比较胸部放射科医生、普通放射科医生和呼吸科医生在电脑辅助下评估肺结节X线片后提出的随访建议

A Comparison of Follow-Up Recommendations by Chest Radiologists, General Radiologists, and Pulmonologists Using Computer-Aided Detection to Assess Radiographs for Actionable Pulmonary Nodules
作者:Meziane Obuchowski Lababede 【View at publisher】 【全球专家评论】
期刊: AM J ROENTGENOL2011年5月5期196卷 专家评级:★★ 循证评级:B

OBJECTIVE:

The primary objective of our study was to compare the effect of a chest radiography computer-aided detection (CAD) system on the follow-up recommendations of chest radiologists, general radiologists, and pulmonologists.

MATERIALS AND METHODS:

A chest radiography CAD system (RapidScreen 1.1) that has been approved by the U.S. Food and Drug Administration (FDA) and a second-generation version of the system (OnGuard 3.0) not yet approved by the FDA were applied to single frontal radiographs of 200 patients at high risk for lung cancer. One hundred patients had actionable nodules (mean size, 16.9 mm) and 100 patients did not. Six chest radiologists, six general radiologists, and six pulmonologists independently interpreted each image first without CAD and then with CAD during blinded reading sessions. The frequency with which readers correctly referred patients for follow-up tests was measured. Differential effects based on nodule size, shape, location, density, and subtlety were tested with multiplevariable logistic regression.

RESULTS:

For patients without actionable lesions, pulmonologists showed an increase in their recommendations for follow-up from 0.46 unaided to 0.52 with CAD (p = 0.001), whereas chest and general radiologists had much lower average rates and were not affected by CAD's false marks (0.26 without CAD vs 0.25 with RapidScreen 1.1 and 0.26 with OnGuard 3.0, p ≥ 0.734). CAD improved all readers' detection of moderately subtle lesions (p = 0.013) but did not significantly increase follow-up rates overall for patients with actionable nodules (0.63 unaided vs 0.63 with RapidScreen 1.1, p = 0.795; and 0.63 unaided vs 0.64 with OnGuard 3.0, p = 0.187).

CONCLUSION:

The effect of CAD on readers' clinical decisions varies depending on the training of the reader. CAD did not improve the performance of chest or general radiologists. Nonradiologists are particularly vulnerable to CAD's false-positive marks.

学科代码:肾脏病学 放射学   关键词:放射 X线片 随访建议
来源: ScienceDirect
ScienceDirect介绍:ScienceDirect 是全球最著名的科技医学全文数据库之一,其直观友好的使用界面,使研究人员可以迅速链接到Elsevier出版社丰富的电子资源,包括期刊全文、 单行本电子书、参考工具书、手册以及图书系列等。用户可在线访问24个学科2200多种期刊, 1,5000多种图书,查看1,000多万篇全文文献。 全球范围内,ScienceDirect获得了134个国家1100万科研人员的认可,每月全文下载量达数百万篇 ,截至2006年11月14日累计全文下载量已突破10亿篇。从2000年起,ScienceDirect由 中国CALIS工程中心组织集团购买。目前,已有200多所高校、中科院 、国家图书馆等机构加入SD中国集团。 马上访问ScienceDirect网站http://www.sciencedirect.com/